3/29/2024 0 Comments Modbus poll framing error![]() ![]() ![]() Note that the first three bytes are added from the last request and after that the read-in is following. It really looks like that there is really one byte missing between "08" and "01". Note: I chose to check the second message you posted, just simply because it's shorter.Īd "failed to read: CRC Error in received frame: 10 bytes: 1e 03 08 01 00 01 00 01 08 98": (Precondition see: ) I also attached (see txt file) the output I got with that very bringup test. ![]() Mod-bus is a master-slave communication protocol that can support up to 247 slaves (which is the same as the individual device address range in Modbus RTU) orga-nized as a multidrop bus. I modified it, to fit the second request sent out by your openHAB "Last request: 1e 03 03 e9 00 04 97 d6", you can find that version at 1.1 Modbus RTU Modbus RTU communication in the M4M network analyzers is done on a 3-wire (A, B and Common) polarity dependent bus according to the RS-485 standard. have you done the communication bringup test mentioned earlier in that thread?. ![]()